Relipowertech 4 kVA Isolation Transformer, 3 phase, 400V to 208V

800 VA single phase isolation transformer for sale, designed to step up 110 volt to 240 volt, step down 240 volt to 110 volt version is available, other voltage can be customizable, provides increased reliability and 95% high working efficiency.

customization Ability

Share

4 kVA Isolation Transformer Features:

  • To step down/up the 3 phase voltage 400V to 208V.
  • Primary and secondary windings are separated by aluminium/copper shield.
  • Available in the circuit of AC 50Hz/60Hz.
  • Better protection, high quality workmanship.

4 kVA Isolation Transformer Specifications

Basics Model RELI-SG4KVA
Phase 3 phase
Capacity 4 kVA
Weight of Aluminium Wire Transformer Open type: 50kg
Protected type: 65kg
Weight of Copper Wire Transformer Open type: 50kg
Protected type: 65kg
Technical Parameters Primary Voltage 400V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage 208V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency 50Hz / 60 Hz
Winding Material Aluminium/Copper wire (Optional)
Work Efficiency ≥95%
Insulation Resistance ≥50 MΩ
Electrical Strength 3000V AC/1 min
Noise <35-65dB (1 meter)
Insulation Grade H level
Wiring Mode Dyn11
Cooling Mode Dry type air cooling
Overload Capacity Allow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection Grade IP 24
Certificate CE, ISO
Warranty 12 months
Working Environment Temperature -15℃~+40℃
Humidity ≤90%RH, without condensation
Altitude <1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients’ requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

4 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer Size Copper Wire Transformer Size
Open type: a*b*c=300*155*310mm Open type: a*b*c=300*155*310mm
Mouting size: d*e=180*125mm Mouting size: d*e=180*125mm
Protected type: A*B*C=300*440*500mm Protected type: A*B*C=300*440*500mm

 

Tips: Characteristics of 4 kVA 3 phase isolation transformer at the AC power output

  1. Avoid the current distortion of non-linear load to affect the normal operation of AC power and influence to the Grid, it plays a role in purifying the power Grid.
  2. Take sample at the input end of this three phase 400/230V to 208/120V isolation transformer, so that the distortion of the non-linear load current will not affect the accuracy of the sampling and the control signal that can reflect the actual situation can be obtained.
  3. If the load is not balanced, it will not affect the normal operation of the stabilized voltage power supply.

Additional information

Weight 16 kg
Winding Material

Aluminum Wire, Copper wire[+$145.79]

Primary Voltage (AC)

120V, 190V, 208V, 220V, 230V, 240V, 380V, 400V, 415V, 440, 460, 480

Secondary Voltage (AC)

120V, 190, 208, 220, 230, 240, 380, 400, 415, 440, 460, 480

Transformer Type

Enclosure Type/Open Type[-$60.00]

With Movable Wheels

Yes/No